DP50RB - AN OVERVIEW

Dp50rb - An Overview

Dp50rb - An Overview

Blog Article

The person is not really allowed to open up the addresses and panel with the process, neither Observe: system disassemble is permitted. To ensure the system overall performance and safety, only Mindray engineers or engineers licensed by Mindray can complete upkeep.

one.two.two Warning Labels Warning Labels Meaning Be sure to cautiously read this guide ahead of use machine. The following labels certainly are a. Tend not to position the product with a sloped floor. Normally the readily available once the technique device may slide, causing own harm or even the device performs Together with the cellular malfunction.

Any time you prevent the scanning as well as picture capture, you must electric power off the technique and disconnect the program through the AC electric power provide, then pull out AC electric power cables. Web site 109: Battery Connecting Board

Our DP-50 Rated units can endure hurricane-power winds as many as 173 mph. Devoted to offering learn wood entry doors to states with even the strictest building demands, DP-fifty Rated Models are DSA’s least Coastal Door Rating which satisfies or exceeds most non-impression constructing needs alongside the east Coastline.

The DP-fifty Skilled is definitely an impressive, high-effectiveness Ultrasound System engineered to assist you to get the insights you will need. The Technique’s impressive engine and high-speed processing deliver excellent image high quality and a complete information and facts administration solution.

five.two.3 Geometric positioning accuracy Longitudinal geometric positioning accuracy  Exam Phase: Do adjustments as just how in screening the maximum depth. History the distance by 20mm Each and every segment to the longitudinal targets line utilizing the measurement caliper; Pick the worth with the greatest error (to 20mm), work out the precision using the formula underneath The measurement caliper needs to be positioned on the higher fringe of the goal, Notice:... Webpage seventy nine Transverse geometric positioning precision  Take a look at Step: Include the scan surface area with the phantom with h2o or pair gel, gently contact the probe Using the scan floor Modify the depth, earning the transverse targets to become displayed during the picture. Adjust the main target stage to be posited beside the transverse targets (the conventional just isn't apparent) Adjust parameters like achieve, TGC, producing Every single transverse targets being Plainly exhibited. Page 80 five.five.2.4 Blackout Spot Take a look at Phase: Include the scan floor with the phantom with water or pair gel, Carefully Make contact with the probe Using the scan surface Adjust the depth at a lessen benefit, and set the main focus at the nearest place to the scan surface. Lessen the value of parameters like AP, Gain until the background noise just could be seen. Web page 81: Software program Improve And Servicing

Highest four periods tasking for one particular transmitted beam, causing outstanding time resolution and higher body charge.

Click on Concur and Commence to simply accept cookies and go straight to the internet site or click More Information to find out comprehensive descriptions of the kinds of cookies and choose no matter whether to simply accept particular cookies although on the positioning.

Pick this selection only on trustworthy private or personalized equipment. Shared or community gadgets may possibly pose a protection hazard to your account and information. Tend not to demonstrate this once more Okay

NOTE: Ahead of uploading the log, be sure the ultrasound technique has been connected to network, or else, the process may perhaps warn “couldn't hook up with server” The server (smtp.

This handbook may referring to info guarded by copyright or patents and will not convey any license under the patent legal rights or copyright of Mindray, or of Many others. Web site nine: Statement

Observe: Make certain that you could potentially pull out and press in the IO board sockets vertically when pulling out and assembling the IO board assembly within the position from the handle. Remove panhead screws with washers M3X6 (four) used to secure the IO board, then you may take out the IO board. Webpage Dp50rb login 116 Eliminate panhead screws with washers (two M3X6) which are fixed on the leading unit, take out the upper baffle and then pull out two cables connecting the leading board to the facility module assembly.

Website page one hundred forty five Clear user interface Equipment: dry smooth cloth, mild soapy drinking water  Process:  Use dry soft fabric to scrub the floor on the program. In the event the system is soiled, moisten the gentle fabric with mild soapy water and wipe off any stains. Use dry tender cloth to get rid of any humidity and allow all challenging surfaces to totally air-dry. Site 146: Clean The Peripherals

After changing the CPU module, key file should be generated once again in accordance with the new MAC handle and published into HDD with the device. Or else, the configuration operate in the merchandise is going to be lost. Immediately after removing the CPU module, Get rid of panhead screws with washers (twelve M3X6) preset on the primary device box, you may take from the board. Page 118 Determine eight-29 Disassemble the User interface Assembly (1) Keep the upper fringe of user interface assembly, and open up the control panel. Determine 8-30 Disassemble the User interface Assembly (2) Right after eliminating a person countersunk head self-tapping screw PT3X10 set about the control panel and acquire out the plug in the keyboard and the primary unit connecting cables, you could remove the control panel assembly.

Performance Take a look at 5.five.1 Examination Procedure Resolution Detection depth Geometric Posture Accuracy Blackout spot examination File the exam visuals 5.5.2 Examination Content material The image utilised Here's only for reference, keep on with the image impact in the real Observe: circumstance. Specifications: Display screen: set the contrast and brightness with the medical application price (or perhaps the default standing) Operation setting: dim space, simulating the clinical software natural environment. Site 76 In condition the transverse resolution tests targets are horizontally exhibited, file the small length of two targets that could be clearly identified. Repeat the operation earlier mentioned to the transverse resolution testing targets at other depths. As demonstrated in determine under. Axial resolution ... Webpage seventy seven When utilizing the convex probe, hold the transverse resolution tests targets to notice: be exhibited near the midline. When employing a linear probe with steer perform, never activate the steer operate when execute the transverse resolution check. Zoom in the area where the targets Situated if essential. The diameter of the target position at a specific depth is equal into the transverse resolution with the depth. Website page 78 5.

Report this page